Add your first device
Add one device, confirm it is answering, and only then move on. Most trouble with a monitoring system traces back to a device that was never really answering in the first place.
Pick a device you can afford to get wrong. A switch you own, on a network you control, with SNMP already enabled. Do not start with the device somebody is asking you about.
Before you start
Section titled “Before you start”For this SNMP example, the device must answer queries from its assigned collector. Run the checks on that collector, preferably as the poller user; a request from your laptop can take a different firewall path. Replace the example address and community with the read-only credentials configured on your device. Numeric OIDs below also work when local MIB name files are not installed.
snmpget -v2c -c 'your-read-only-community' switch.example.net .1.3.6.1.2.1.1.1.0If that returns a description string, continue. If it times out, fix that first. No amount of configuration in the web interface will make an unreachable device answer.
Then check the table you actually want to graph, because a device can answer
sysDescr and still refuse the interface table.
snmpwalk -v2c -c 'your-read-only-community' switch.example.net .1.3.6.1.2.1.2.2.1.2The second OID is the ifDescr column. You want one row per exposed interface.
An empty result can mean a restricted SNMP view or an unsupported table; an
authorization error points to credentials or access policy. Inspect the returned
error before changing the device or Kadupul configuration.
Two facts about SNMP versions decide things later, so settle them now.
| Version | What it means for you |
|---|---|
| v1 | No Counter64 support. Fast links can wrap 32-bit octet counters multiple times between polls, making the rate ambiguous |
| v2c | Supports Counter64 when the agent exposes it; community strings are sent in clear text |
| v3 | Supports authentication and encryption with authPriv; choosing v3 alone does not enable both |
Prefer v3 with authPriv where supported, or v2c on a restricted management
network. Select the 64-bit interface graph type as well as the SNMP version.
If the device only speaks v1, consider the polling interval and traffic rate in the
failure table at the bottom of this page. SNMP covers the
credential fields in full.
Decide three things before you open the form
Section titled “Decide three things before you open the form”The credentials. Exactly the ones you tested above, including the port if it is not the default.
The availability method. This is how Kadupul decides the device is up, and it is independent of whether collection works. The shipped choices are none, ping, SNMP uptime, SNMP description, SNMP getNext, and two combinations of ping with SNMP uptime, one requiring both and one accepting either.
Prefer an SNMP method for a device you are polling over SNMP. It tests the thing
you depend on. ICMP ping needs a raw socket, which needs privilege the web and
poller users do not normally have, so a device that answers ping from your shell
can still be reported down. A TCP ping against a port you know is open avoids that.
The device template. Choose one that matches the hardware.
Add it
Section titled “Add it”- In the legacy Devices page (
host.php), choose Add. Device creation and graph setup still use this page during the Symfony migration. Enter a description, hostname or address, assigned collector, SNMP version, and credentials. - Set the availability method you chose.
- Choose the device template.
- Save, confirm the device is enabled, and read its availability/SNMP panel. A saved database record is not evidence that collection has succeeded.
What the device template decides
Section titled “What the device template decides”A device template associates graph templates and data queries with the device. A data query walks a table on the device, such as its interfaces, and produces one index per row. Applying the template also runs its data queries to populate those indexes. With graph automation disabled, those associations do not by themselves create graphs. When graph automation is enabled, template/query hooks can create graphs under matching rules; inspect the existing graphs before adding another copy.
Changing a template can alter associations and run those hooks again. It is not a reset of existing graphs or data sources. Check the selected template and queried indexes before applying it to a device that already has history.
Those indexes are why you pick interfaces from a list rather than typing OIDs. Templates and Data queries and indexes cover both properly.
Read the status panel
Section titled “Read the status panel”When the device is saved with an SNMP availability method, Kadupul opens a session and reports back. This is the check that matters, and it is the one people skip.
| What you see | What it means |
|---|---|
| System and uptime queries succeed | The panel can read basic SNMP metadata. This does not yet prove interface collection |
| Location or Contact is empty | These optional metadata fields may be unset; emptiness alone is not a collection failure |
| SNMP not in use | No community or username on the device, or the version is set to none |
| Session SNMP error | Session setup failed; inspect the displayed error, credentials, protocol and connection settings |
| System SNMP error | Reading sysDescr failed; check the returned error, agent view, credentials and reachability |
| Host SNMP error | Neither description nor uptime came back |
Uptime shown as U |
Uptime was not readable. Some devices genuinely do not report it |
If the availability method includes ping, a separate ping result appears below. Read both. A device can pass one and fail the other, and which one fails tells you where to look.
A blank system description does not prove that collection is failing. The code accommodates agents with an empty description and usable uptime. Disabled devices bypass the availability check, and non-SNMP availability methods do not show this SNMP panel. Verify the actual query and poller cache next.
Create the data sources and graphs
Section titled “Create the data sources and graphs”For a new device without automation-created graphs, the next step is to create the graph and its data source. Check Data Source List and View Poller Cache on the device page instead of assuming they are empty.
From the device page, choose Create Graphs for this Device. For a switch this means running the interface data query, picking the interfaces you care about, and choosing a graph type for them. Pick two or three interfaces, not all forty-eight. You are proving the path works, and a small first batch is far easier to read in the next step.
An indexed graph associates data sources with the chosen interface and prepares their poller-cache entries; compatible existing sources can be reused. The graph creation response is not proof of polling. Check that the cache contains the expected device, interface OIDs and RRD path.
Confirm it is collecting
Section titled “Confirm it is collecting”Wait for scheduled collection cycles, then check both timestamps and values. An empty graph can mean startup normalization, an unknown value or failed collection. Two counter readings are necessary to calculate a rate, but two poller runs do not guarantee a completed, valid archive bucket.
Check three things, in this order.
The poller ran. Look for the end-of-run summary in the configured log. If it is absent, check scheduling, log destination and permissions, and whether the poller exited before completing. See Logging.
The file exists and is recent. Copy the actual RRD path from the data source or poller cache; do not guess it from the hostname. Paths and names can be customized. See File layout. Ask RRDtool when the file was last written:
rrdtool last /path/to/rra/the_actual_file.rrdrrdtool lastupdate /path/to/rra/the_actual_file.rrdrrdtool fetch /path/to/rra/the_actual_file.rrd AVERAGE --start end-30m --end nowThe timestamp should advance on successful writes. A recent timestamp can still
accompany an unknown value, and buffered writes can delay the on-disk timestamp.
For rrdcached or Boost, check that component’s flush state as well.
The value is not unknown. lastupdate shows the latest supplied values; for
a counter these are counters, not computed traffic rates. Inspect completed rows
from fetch for finite rates. Startup timing, step alignment, heartbeat, bounds
and the archive’s unknown-data threshold all affect when a usable row appears.
Do not diagnose a fault from the first two rows alone. If unknowns persist, inspect
the collected values, data-source type, heartbeat and poller errors.
Common first failures
Section titled “Common first failures”| Symptom | Usual cause |
|---|---|
| Saves, but system-description lookup reports an error | Check credentials, agent view and collector reachability; an empty description alone is not sufficient evidence |
Session SNMP error from Kadupul, snmpget works from your laptop |
Firewall path differs, or the agent restricts by source address |
| Device shows down, but SNMP data arrives | Availability set to ICMP ping, which cannot open a raw socket |
| Description appears, no data | Poller not scheduled, or running as a user that cannot write the RRD directory |
| Data query returns no interfaces | Agent view excludes the interface table, or the device needs a reindex |
| First value unknown, then fine | Normal for a counter. It needs two readings to produce a rate |
| Unknown values persist | Failed collection, invalid values, type/bounds mismatch, heartbeat or archive normalization |
| Data for a while, then gaps | Poller taking longer than its interval, or the device rate limiting SNMP |
| Counter rates are implausible | Multiple 32-bit wraps, a counter reset, units or data-source settings; use supported 64-bit counters on fast links |
| Interfaces graph the wrong ports after a reboot | Indexes shifted. The data query needs a reindex method that notices |
The last one is worth understanding before you have a hundred switches: SNMP interface indexes are not guaranteed stable across a reboot or a module change. The reindex method on a data query is what keeps a graph pointed at the same physical port. Data queries and indexes explains the choices.
When you have one device collecting cleanly, add the rest in bulk rather than one at a time. Discover devices automatically and the command line tools in Command line tools both beat repeating this page fifty times.
Next: Read your first graph.
Documentation license: CC BY-SA 4.0Site code license: GPL-3.0-or-laterKadupul is not affiliated with or endorsed by The Cacti Group.