Skip to content
Kadupul is pre-alpha. Validate these procedures in an isolated test installation.

Scale the poller

Scaling the poller is one question: does a collection run finish before the next one starts? Everything below is about answering that and then moving the answer back to yes.

Read Architecture first if you are not clear on which part does the collecting.

There are two intervals and they are not the same setting.

What it is Allowed values
Launcher interval How often the operating system starts the collector, from cron or from the cactid service 60 or 300 seconds
Poller interval Base collection cadence; individual data source steps can be longer 10, 15, 20, 30, 60 or 300 seconds

When the poller interval is shorter than the launcher interval, one launch performs several collection passes in a loop. The number of passes is the launcher interval divided by the poller interval.

The budget for the whole launch is derived from those two numbers: passes multiplied by the poller interval, minus two seconds. That is the wall clock the run is measured against.

Three distinct things, and they produce three distinct log lines.

The run is cut off. When the elapsed time passes the budget, the poller logs that the maximum runtime was exceeded, writes its statistics, and exits. Work that has not produced a sample can leave a gap. Samples already accepted into the durable queue can remain pending for a later successful RRD write; an overrun does not imply every unflushed measurement was discarded. Inspect queue depth and logs alongside the graph, and do not clear retained rows to make the next run look clean.

The next run notices the wreckage. At startup the poller counts process rows that were never closed out and warns that processes were detected as overrunning a polling cycle. Investigate unfinished or stale process records and actual running children; the warning alone does not identify the bottleneck.

The clocks drift apart. If more time passed since the last run than the budget allows, the poller warns that the launcher is out of sync with the poller interval. This one is usually the launcher, not the poller: a cron entry at the wrong frequency, a stopped service, or a host that was asleep.

These paths call the admin notification helper. Delivery depends on configured recipients, notification controls and functioning mail transport; a log warning does not prove that an email arrived. See Email notifications.

There is a fourth case that is not an overrun. If the poller is started again sooner than it expects, it logs that it is configured to run too often and exits without collecting. --force bypasses that timing check; use it only during a controlled diagnostic with scheduled and other manual launches stopped. It does not add capacity or make overlapping collection safe.

Every completed run writes one statistics line to the log. It carries the elapsed time, the collection method, the process and thread counts, the number of devices, devices per process, data sources, and RRD files processed.

Trend elapsed time, tail latency, queue depth and failed updates. Investigate even an isolated near-budget run when it causes gaps; sustained growth helps identify when capacity or collection behavior needs to change.

Two dials, and they do different things.

Dial Unit of work it divides Which collector uses it
Processes Devices, split into contiguous ranges of device id Both
Threads Items within one device Spine only

The consequence is the part people trip on: a process is assigned whole devices. One device with five thousand data sources cannot be spread across processes. It lands in one process and that process takes as long as it takes. Adding processes does nothing for it.

Both values are held per data collector, not globally. The values on the settings page are presets applied when a new data collector is created. Changing the preset does not change an existing collector.

There is also a per-device thread count, which is how a single large device gets divided. It applies only to the C collector.

Balance Process Load uses accumulated item counts to choose boundaries between whole devices in device-id order. It does not split one device or guarantee equal item counts, and item count is not execution time. Compare per-process timing before and after enabling it on an isolated representative workload.

The PHP collector, cmd.php, ships with the application. Kadupul plans to maintain a Spine fork, but its source location and validated builds are not yet documented. Use PHP until that evidence is available. The Spine comparisons, thread settings and commands below describe inherited behavior, not an available or supported Kadupul deployment.

PHP collector Spine
Parallelism Processes only Processes and threads
Thread setting Forced to 1 regardless of configuration Honoured
Script server One per process, not configurable 1 to 15 per process, configurable
Script timeout Not applied Applied, default 25 seconds
Install Ships with the code Planned fork; no validated Kadupul build documented

The forced thread count is worth stating plainly: if the collector is set to the PHP one, the runtime thread variable is set to 1; this does not rewrite the stored collector thread setting. Scaling the PHP collector can involve more processes, and the guidance in the source is to stay at or under twice the CPU core count.

Spine configuration and command behavior require validation against the exact binary being evaluated. The PHP application source alone does not establish its configuration search order, thread behavior or side effects.

Inherited examples for an isolated Spine evaluation, not validated Kadupul commands:

Terminal window
spine --first=42 --last=42 --threads=1 --verbosity=HIGH --stdout
spine --hostlist='42,43,51' --readonly

--readonly is intended to avoid result writes. It still contacts devices and runs collection scripts; validate its side effects in an isolated test first.

Threads are not free. Each spine thread holds its own database connection, and so does each script server.

estimated worker connections = processes * (threads + script_servers)

This is the estimate in the application settings help, not a measured upper bound. Sum it across collectors and add capacity for poller parents, web requests, maintenance and other clients. Measure actual peak connections and rejected connections before choosing the database limit; increasing it also consumes resources.

Connection exhaustion can cause missing samples, but rotating gaps are not a unique diagnosis. Confirm it with database connection metrics and application errors.

There is a mode that stops the poller from writing to RRD files on every pass. Results accumulate in a database table instead and are flushed in bulk, either on a timer or when a graph asks for the file. It trades a large number of small writes for a small number of large ones.

Two facts about it that matter operationally:

  • It is required when you have remote data collectors. This is not advice, it is a condition the software states.
  • The buffer table is durable, not in-memory, so unflushed samples survive a restart. They also mean your RRD files are behind your database. See Back up and restore before you snapshot anything.

The main in-flight poller_output queue is also InnoDB in this revision. Storage preflight rejects a MEMORY queue; increasing the heap-table limit does not resolve that refusal. With producers stopped and a matched backup retained, convert an inherited unsuitable queue explicitly, then check storage as each service account:

Terminal window
php cli/upgrade_database.php --migrate-poller-queue
php cli/upgrade_database.php --check-rrd-storage

These are separate operations. Preserve pending rows and monitor database disk space and queue age as well as row count. See Upgrade safely for queue selection, service-account trust checks and restart prerequisites.

A remote data collector is a second machine running the same code with a different collector id, polling a subset of devices and writing results back to the central database.

Move to one when the bottleneck is on the collecting side rather than the storing side:

  • The poller host’s CPU is saturated during a run and idle between runs.
  • Round-trip latency to a group of devices dominates the run, and that group sits behind one link.
  • A site is on the far end of a WAN you do not want to poll across.
  • You need isolated-site collection, and have validated offline buffering and recovery for that collector before relying on it.

Remote collectors do not remove central database or RRD write limits. Measure central ingestion and flush capacity before increasing collection throughput; extra producers can increase an existing backlog.

Each collector carries its own process and thread counts, its own database credentials, and a synchronisation interval, which defaults to two hours. There is a command line tool to force a full synchronisation rather than waiting.

The central install can replicate the web site and plugin code out to remote collectors so they update themselves. That replication can be turned off if you deploy code some other way.

Use this table to form hypotheses, then verify them with logs and measurements. Several limits can occur together. Spine options remain unvalidated here.

Observation Limit What to change
Launcher out of sync warning, poller otherwise fast Scheduling delay, prior overrun or host interruption Inspect launch history and process state
Run time flat, one device always late Slow responses, expensive scripts or concentrated work Time its input methods and review timeout/retry behavior
Run time scales with device count, CPU saturated Collector CPU pressure Measure whether more processes help; consider collector placement
Run time scales with device count, CPU idle Network, script or database waits Measure wait sources before changing concurrency
Missing samples on a rotating set of devices Connections, timeouts or other collection failures Check errors, connection metrics and retained queues
Run time fine, RRD writes slow, disk busy Storage Deferred RRD writes, or faster disk
Everything slow including the web interface Database Buffer pool size, then the database host

Two traps worth naming.

Changing the base interval is not the same as changing every data source step. Reconcile profiles, cached item steps and RRD heartbeat/step definitions. Rebuilding the cache does not reshape existing RRD files. See Data retention and Time and intervals.

A faster interval multiplies everything. Going from 300 seconds to 60 does not make the work five times cheaper. Sources configured for that faster cadence are collected more often; sources retaining longer steps need not run on every base pass. Measure the resulting load rather than assuming every pass has equal work.

Documentation license: CC BY-SA 4.0Site code license: GPL-3.0-or-laterKadupul is not affiliated with or endorsed by The Cacti Group.