Saltar para o conteúdo
This is inherited 1.2.31 documentation. A supported Kadupul release or migration path is not yet available. Validate procedures before use.

Tune database performance

Este conteúdo refere-se a 1.2.31. Consulte a versão mais recente para obter documentação atualizada.

As páginas ainda não traduzidas são apresentadas em inglês com um aviso.

The database is not where measurements live. See Architecture if that is new. It is where definitions, credentials, the collector’s work list, and results in flight live, and on a large install the last two are what hurt.

Before tuning anything, work out which limit you hit. A collection run that overruns its interval is usually the collector, not the database; start with Scale the poller. Come here when the symptom points at the database: lock waits in the log, the interface slow on pages that list things, or memory tables filling up.

Most tables in the schema are definitions and stay small. These do not.

Table Grows with Engine
poller_item One row per data source item, per collector InnoDB
host_snmp_cache One row per index per queried field per device InnoDB
poller_output Pending measurements, including retained failed writes InnoDB
poller_output_boost Results waiting to be written to disk InnoDB
poller_output_realtime Real-time graph requests InnoDB
poller_reindex Data query re-index checks per device InnoDB
data_source_stats_* One row per data source per period Mixed

poller_item is the collector’s work list and the one that decides how heavy a collection pass is. It carries the device address, the SNMP credentials, the expanded RRD file path and the arguments, all denormalised, because the collector reads it once per pass and cannot afford a join.

host_snmp_cache is the one that surprises people. A switch with 400 ports and a query returning eight fields per port is 3200 rows from one device. It is indexed heavily for the same reason: everything that builds a graph name reads it.

Several tables are declared as memory tables on purpose: the hourly statistics caches, the boost and discovery work registries, and the process registry. The poller_output results queue is not one of them. It is InnoDB, and the upgrade converts an existing MEMORY copy.

Their contents are lost on a database restart, and they are capped by the server’s memory table size limit, not by disk. Exceed it and inserts fail.

Deferred-write queues consume database disk space; monitor row counts, oldest pending timestamps and free space. A failed flush can retain a growing backlog.

Turning on deferred RRD writes moves load. Instead of writing every RRD file every pass, results accumulate in a durable table and are flushed in bulk. Disk seeks go down. Database volume goes up, sharply.

The settings that govern the flush:

Setting Default What it controls
Update interval 1 hour How often everything is flushed regardless
Maximum records 1,000,000 Row count that triggers an early flush
Data source items per pass 50,000 How much one flush pass reads at a time
Number of processes 1 Parallel flush processes
Memory limit 1 GB Per flush process
Maximum run time 20 minutes Warns in the log if exceeded

Raising the items-per-pass value makes flushes faster and makes graphing slower while one is running, because both compete for the same tables. If graphs go slow on the hour, that is the setting to lower first.

There is also an option to insert collector results straight into the boost table, skipping poller_output. The normal queue is already durable, so this is not a MEMORY-to-disk choice. Benchmark throughput and queue age before relying on any speedup.

See High volume writes for the shape of the tradeoff.

Two scripts, doing different things, with names close enough to confuse.

Terminal window
php cli/analyze_database.php

This runs an analyze over every table in the database. It recalculates index cardinality, which is what the query planner uses to decide between an index and a scan. Stale statistics on a large install produce a planner that picks a scan on a table with millions of rows, and the symptom is one page that used to be fast and is now not.

It writes nothing to your data. If binary logging is on, it analyzes without writing to the log so replicas are not disturbed. Run it on a schedule; it is cheap and it is the first thing to try when a specific query went slow without the data changing shape.

Run from a remote collector it operates on the main database by default. Pass --local to act on the collector’s own.

Terminal window
# report only
php cli/audit_database.php --report
# print the statements without running them
php cli/audit_database.php --alters
# run them
php cli/audit_database.php --repair

This compares the live schema against a canonical record of what every table, column and index should be, and produces the statements needed to close the gap. It also normalises storage engine and row format while it is there: a table still on the older engine is moved to InnoDB with dynamic rows, and the table’s existing collation is preserved rather than reset.

It refuses to run when the code version and the database version disagree, and tells you to upgrade first. That guard is correct. Do not work around it by passing --upgrade unless upgrading is what you meant to do.

Use --alters before --repair, every time. A schema repair on a large table is a long-running alter that locks, and you want to know which tables are in the list before you start rather than during.

A separate repair utility handles table-level corruption and damaged template records. That is a different job from a schema audit; reach for it when the symptom is a table the server reports as broken, not a column that is the wrong width.

These come from the recommendations the install itself checks. Values are starting points, not answers; the right number depends on the size of the box.

Variable Recommendation Why
innodb_buffer_pool_size About a quarter of system memory Holds tables and indexes in memory. Size it against the on-disk size of the database directory.
max_heap_table_size A noticeable fraction of system memory Caps the memory tables. Does not size the InnoDB poller_output queue.
tmp_table_size Same allowance Keeps subquery temporaries in memory.
max_allowed_packet 16 MB or more Collector synchronisation moves large blocks to remote collectors.
max_connections 100 or more Collector processes multiply: processes times threads plus script servers plus one, with headroom for logins.
innodb_file_per_table On Keeps tablespaces separate and manageable.
innodb_flush_log_at_timeout 3 seconds or more Makes disk writes more sequential on high I/O systems.
innodb_io_capacity 5000 on SSD Roughly 200 times the number of drives on spinning disks.
join_buffer_size, sort_buffer_size Modest Allocated per connection. The sum of the per-connection buffers plus the server’s own memory should stay under 80 percent.
character_set_server utf8mb4 Some characters need more than one byte.
collation_server utf8mb4_unicode_ci The matching collation.

The per-connection buffers are the ones people get wrong. They look like a free speedup until you multiply them by the connection count from the row above.

How the application behaves when the database struggles

Section titled “How the application behaves when the database struggles”

Worth knowing, because the symptoms are distinctive.

Lock waits and deadlocks are retried. A statement that fails on a deadlock, a lock wait timeout, or a lock table error is retried after a short pause, up to around 30 attempts, before it gives up and logs. So a database under lock pressure does not fail loudly. It gets slower, and a collection pass that used to finish in 30 seconds takes four minutes. Look for the retry messages in the log before concluding the collector is slow.

A dropped connection is retried too. The connection is re-established after a pause and the statement runs again, a few times. Again, the symptom is latency, not an error.

An oversized statement is not retried. A statement that exceeds the server’s packet limit is logged and abandoned. If that happens during a bulk flush, the results in that batch are lost. This is the reason the packet size recommendation exists.

The session SQL mode is adjusted on connect. Strict modes and a few others are removed from whatever the server hands out, and a small set is added. Setting them globally on the server will not make the application behave differently, so do not spend time there.

Analyze is not repair, and repair is not upgrade. Three scripts, three jobs. Running the wrong one because the symptom is vague wastes a maintenance window.

A schema repair on a large table locks it. Preview with --alters, size the window against the largest table in the list, and do it when collection is stopped if you can.

The retry behaviour hides the problem. By the time something reports a failure, it has already been slow for a while. Watch collection run duration, not just error counts.

Growth is driven by the number of data source items, not the number of devices. One device with a 400-port query outweighs 50 devices with three graphs each. Count rows in the collector’s work list, not entries in the device list.

Statistics collection is optional and it costs rows. The per-period statistics tables hold one row per data source per period. On a large install that is a real table. Leave the feature off if nothing reads it.

Licença da documentação: CC BY-SA 4.0Licença do código do sítio: GPL-3.0-or-laterO Kadupul não é afiliado nem aprovado pelo The Cacti Group.