콘텐츠로 이동
This is inherited 1.2.31 documentation. A supported Kadupul release or migration path is not yet available. Validate procedures before use.

Monitor a switch

이 콘텐츠는 1.2.31에 관한 내용입니다. 최신 문서는 최신 버전을 확인하세요.

아직 번역되지 않은 페이지는 안내문과 함께 영어로 표시됩니다.

A switch is the case data queries exist for. You do not know how many ports there are, the count changes, and every port needs its own data source. See Templates for what a data query is; this page is about getting one right.

Confirm the device answers, from the machine the poller runs on.

Terminal window
snmpwalk -v2c -c public switch.example.net ifName

Use SNMP v2c or v3. The 64-bit interface counters are SMIv2 objects and cannot be retrieved over v1. A v1 device gives you the 32-bit counters and nothing else.

The device template decides which data queries and graph templates are offered when you add the device. Kadupul inherits the template set Cacti ships, which includes a generic SNMP device template and a number of vendor ones.

Port discovery comes from the same place whichever you pick: the interface data query, defined in resource/snmp_queries/interface.xml. If no template matches your hardware, take the generic one and attach the interface query to it.

The query walks ifIndex to find the ports and reads ifNumber to know how many to expect. Then it collects a field set per port.

Field OID Used for
ifIndex .1.3.6.1.2.1.2.2.1.1 The SNMP table position
ifName .1.3.6.1.2.1.31.1.1.1.1 Short port name, Gi1/0/3
ifDescr .1.3.6.1.2.1.2.2.1.2 Longer description
ifAlias .1.3.6.1.2.1.31.1.1.1.18 The interface description you configured
ifHwAddr .1.3.6.1.2.1.2.2.1.6 Port MAC
ifSpeed .1.3.6.1.2.1.2.2.1.5 Speed in bit/s, 32-bit
ifHighSpeed .1.3.6.1.2.1.31.1.1.1.15 Speed in Mbit/s
ifOperStatus .1.3.6.1.2.1.2.2.1.8 Up or down
ifInOctets / ifOutOctets .1.3.6.1.2.1.2.2.1.10 / .16 32-bit byte counters
ifHCInOctets / ifHCOutOctets .1.3.6.1.2.1.31.1.1.1.6 / .10 64-bit byte counters

Run the query once against the device. It returns a table of discovered ports. Read that table before creating anything, because it is the evidence for every decision below.

The interface query offers several traffic graph templates. The ones worth knowing:

Graph template Reads
In/Out Bits ifInOctets, ifOutOctets
In/Out Bits (64-bit) ifHCInOctets, ifHCOutOctets
In/Out Bits (64-bit, 95th) The same, with a 95th percentile line
In/Out Bits (64-bit, BW) The same, against the interface speed
Status (Up/Down) ifOperStatus
In/Out (Errors/Discards) ifInErrors, ifInDiscards, ifOutDiscards, ifOutErrors

Take a 64-bit template unless you have a reason not to. A 32-bit octet counter holds 4294967295. A gigabit port at line rate fills that in about 34 seconds. At a 300 second step, the poller cannot distinguish one wrap from seven, and COUNTER only corrects a single wrap between samples. The graph is not noisy in a way that looks wrong; it is quietly low.

Check the counters are actually populated before you build hundreds of graphs. The high capacity objects are optional and some agents leave them empty.

Terminal window
snmpwalk -v2c -c public switch.example.net ifHCInOctets

An empty walk means every sample will be recorded as unknown, and the graph will be a flat gap rather than an error.

A traffic data source takes its maximum from the speed discovered at the moment the RRD file was created. ifHighSpeed is preferred, ifSpeed is used when it is absent, and a configured default applies when both are zero.

That value is written into the file. A port discovered at 100 Mbit and later negotiated up can end up with a ceiling below its real traffic, and RRDtool records anything above the ceiling as unknown. If a port starts showing gaps at high load after a speed change, this is the first thing to check.

This is the part that costs history when it is wrong.

Each data source records two things about its port: which field identifies it (the index type) and that field’s value. On every reindex, the port is found again by asking which SNMP index currently carries that value in that field. The data source follows the value, not the table position.

So the question is which field carries the value.

The interface query declares a preference order: ifName, then ifDescr, then ifHwAddr, then ifIndex. Kadupul takes the first one that passes two tests against the values the device returned during discovery.

  1. Every discovered port has a value for it.
  2. No two ports share a value.
Field Survives Fails when
ifName Reboots, reseats, renumbering The agent leaves it blank, or repeats it across stack members
ifDescr Usually the same on switch hardware On servers it is a kernel name and can change
ifHwAddr Reboots A replaced card has new MACs, which is the case you were guarding against
ifIndex Nothing worth relying on Reseat, reboot or firmware change renumbers the table

If the query falls through to ifIndex, treat that as a finding rather than a result. It means every field above it failed one of the two tests on this device, and your port history is now attached to a number the switch is free to reassign.

The tests run against whatever the device returned during that discovery. Discover a chassis with a line card pulled, and a field that looked unique across the partial set may not be unique across the full one. Discover when the hardware is complete.

Set per device, per data query. It decides when Kadupul re-reads the index fields.

Method Triggers on Cost
None Nothing; manual or scripted only Free
Uptime The device’s SNMP uptime going backwards One comparison per cycle
Index Count The number of discovered indexes changing One count per cycle
Verify All Every polling cycle The setting’s own description calls it very expensive

Uptime is the default and it suits most switches, because a reboot is the event that renumbers indexes. Index Count catches a card added or removed without a reboot, but not a swap that leaves the count unchanged. Verify All is for a handful of devices that misbehave, not for a fleet.

Reindexing does not run against a device that is down or disabled. A card reseat that also takes the device offline gets reindexed on the first cycle after it answers again, not during the outage.

To force one:

Terminal window
php cli/poller_reindex_hosts.php --id=42
php cli/poller_reindex_hosts.php --id=all

If the index value is gone from the discovered set, the data source is marked an orphan rather than deleted. It stops collecting and its RRD file is left where it is. Put the port back, reindex, and it reattaches with history intact.

A data query can declare that orphans should be removed outright. The interface query does not, which is the behaviour you want.

Two per-device settings matter once port counts get high. The number of OIDs issued per SNMP get request defaults to 10; raising it cuts round trips on a device with several hundred ports. The number of threads used for the device defaults to 1.

Change one at a time and watch the poller runtime, because both trade device load against wall clock.

Symptom Cause
Graphs created, every sample unknown 64-bit counters not implemented, or the device is on SNMP v1
Counters jump to absurd values 32-bit counter wrapping more than once per interval
Gaps only at high load RRD maximum fixed from a stale discovered speed
Port history attached to the wrong port after maintenance Index resolved to ifIndex
Poller logs a warning about bad SNMP indexes Data sources left with no index; reindex, delete or disable them
Ports discovered, nothing collecting Data sources with an empty index produce no poller cache entries

문서 라이선스: CC BY-SA 4.0사이트 코드 라이선스: GPL-3.0-or-laterKadupul은 The Cacti Group과 제휴 관계가 없으며 해당 그룹의 승인을 받지 않았습니다.