There are two intervals, not one, and they belong to different things. How often the collector runs is a property of the installation. How often a data source expects a value is a property of that data source, fixed into its file at creation. Most timing confusion comes from treating them as the same number.

Number Belongs to Set by Changeable later
Polling interval The whole installation A setting, from ten seconds up to five minutes Yes
Step One data source Its profile, at creation Not without rebuilding the file
Heartbeat One field in one data source Its profile, at creation Only by tuning the file

If a data source’s step equals the polling interval, every cycle collects it. There is no scheduling to do, and the shipped default has both at five minutes for exactly that reason.

A data source on a ten minute step, in an installation that polls every five minutes, should be read every other cycle. Kadupul handles that with a countdown stored on each work list row. Only rows whose countdown has reached zero are selected; every row in range then has the polling interval subtracted from its countdown, and a row that falls below zero is reset to its step minus one interval.

Left alone, that scheme would make every long-step item come due in the same cycle, producing a heavy cycle followed by light ones. Process leveling exists to prevent that. It gives the long-step data sources on one device staggered starting offsets, spread across the number of cycles that fit inside their step, so the work lands evenly.

This is worth knowing because it means a data source can be correctly configured, correctly cached, and still produce nothing on the cycle you happen to be watching. Before concluding an item is broken, check whether it was due.

When the step is shorter than the interval

Section titled “When the step is shorter than the interval”

This one cannot be made to work. A data source whose step is shorter than the polling interval is asking for samples more often than anything runs. Kadupul detects it while building the work list, logs a warning, and mails the administrator saying to lower the polling interval to match and rebuild the cache.

The file is not damaged by this. It simply has more slots than there are values to fill them, so the graph is a comb.

The heartbeat is the maximum permitted interval between updates before input is treated as unknown. It comes from the profile when the data source is created; it is not an extra grace period added to the step.

The shipped profiles do not follow one rule.

Profile Step Heartbeat Update interval limit
Five minute 300 600 10 minutes
One minute 60 600 10 minutes
Thirty second 30 1200 20 minutes

The short-step profiles are deliberately forgiving, because at a thirty second step a single slow device would otherwise punch a hole in a graph every time it hesitated. The trade is that an outage takes twenty minutes to show up as a gap rather than one. If you want outages visible promptly on a fast-stepping data source, that is a decision to make at profile creation, not afterwards.

The failure mode at the other end is worse. A heartbeat at or below the polling interval means that any jitter at all crosses the threshold, so the file records unknown constantly and the graph is mostly holes. Kadupul’s file audit reports this case by name.

That audit is also where step and heartbeat drift shows up. If a profile is edited after its data sources exist, the database can be brought back into agreement with the profile, but the files cannot: their step was written at creation. The audit reports the disagreement rather than pretending to fix it.

What is stored is not what the device said

Section titled “What is stored is not what the device said”

RRDtool places values on fixed step boundaries. A sample that arrives between two boundaries is apportioned across the slots it spans, and a slot that receives no sample within the heartbeat becomes unknown rather than being filled in.

For a counter this is the whole point: the stored value is a rate, computed against the elapsed time between updates, so a slightly late reading still yields a correct rate. For a gauge it is a mild surprise. A brief spike sampled just off a boundary is spread across two slots and looks smaller than it was. Peaks are never quite as sharp in the file as they were on the wire, and no archive setting recovers that.

The timestamp on a sample does not come from the device, and it does not come from the moment the device answered. It is supplied by the database when the collected values are inserted.

Collectors buffer their results and write them in batches, flushing on a change of device or when the buffer fills. The timestamp is evaluated once per batch, so every value in one batch carries the same one.

The consequences are not obvious, so they are worth spelling out.

A device with a wrong clock still graphs correctly. Its notion of time never enters the pipeline. This is genuinely useful: you do not have to fix NTP on a thousand switches to trust your graphs.

A wrong clock on a collector or its database does shift the data. Values get stamped into the wrong slots, and on a file that is already partly written, an update whose time is not after the last one is refused outright. A collector whose clock jumps backwards stops recording until real time catches up.

Time inside a cycle becomes jitter. A device polled near the end of a long run is stamped later than one polled at the start, even though both belong to the same cycle. On a heavily loaded collector that jitter can become a meaningful fraction of the interval, and it is one of the ways a heartbeat set too close to the step starts producing gaps.

The timezone of the database sits in the middle of the round trip. The timestamp is written as a database timestamp and converted back to an absolute time by the database when it is read. Changing that configuration underneath a running installation changes where values land.

A data source with more than one field, such as an interface with bytes in and bytes out, is collected as separate work list items producing separate results. They are reassembled into one update by matching their timestamps.

A set that is not complete is held back rather than written short, so that a file never records a half reading. Normally both halves are in the same batch and share a timestamp, so this is invisible. When they are split across batches they carry different timestamps, neither group is complete, and that cycle produces nothing for that data source. The leftovers are swept at the start of the next cycle.

Updates are also sorted into ascending time order before being written, because a file will not accept a value older than its last update.

When RRD writes are deferred and applied in bulk later, the recorded timestamp travels with the value and the batch is written in time order. A sample collected at noon and written at one o’clock still lands in the noon slot.

That is the property that makes deferred writing safe. It is also why a backlog shows up as a graph that stops at the present and then fills in behind you, rather than as data compressed into the moment it was flushed.

A collector that passes the polling interval mid-run stops and logs it. The items it had not reached produce no values that cycle. One such cycle is interpolated away if the heartbeat allows it. A collector that overruns consistently produces a graph full of small gaps, which reads as a flaky network and is actually a capacity problem.

Scale the poller covers what to do about it. The ordering of a run, including the overrun guards, is in Poller lifecycle.